PORTABLE AUTOMOTIVE GAS ANALYZER
Type : Bensin-Solar
Spesifikasi :
1 | UJI EMISI KENDARAAN BENSIN | |||
▪ | Parameters | : | Range | Resolution |
O2 | : | 0 - 25% | 0,01% | |
CO | : | 0 - 9,999% | 0,1% | |
CO2 | : | 0 - 20% | 0,01% | |
HC | : | 0 - 10,000 ppm | 1 ppm | |
NOx | : | 0 - 5000 ppm | 1 ppm | |
AFR | : | 0,0 - 99,0 | 0,01 | |
▪ | Measuring Item | : | CO, HC, CO₂, O₂, (air surplus rate), | |
AFR, Nox | ||||
▪ | Measuring Method | : | HC,CO, CO₂- NDIR(Non-dispersive infrared) | |
: | O₂, NOx-Electro Chemical | |||
▪ | Repeatability | : | Less than ± 2% FS | |
▪ | Response Time | : | Within 10 seconds (more than 90%), | |
▪ | Warming up time | : | 2 - 8 minutes | |
▪ | Flow rate | : | 4 - 6 L/min | |
▪ | Power supply | : | 220V | |
▪ | Printer tipe | : | Built-in thermal printer | |
2 | UJI EMISI KENDARAAN SOLAR | |||
▪ | Measuring item | : | Smoke opacity ( %, k [m-1] ) | |
: | RPM (option), °C (option) | |||
▪ | Principle | : | Light extinction method | |
▪ | Light source | : | Green LED(565nm) | |
▪ | Detector | : | Photo diode | |
▪ | Range | : | 0.0~100.0% (0.00~21.42m-1 ) | |
▪ | Accuracy | : | Less than 1% | |
▪ | Warm-up time | : | 3~6 minutes | |
▪ | Display time | : | 4 times /sec | |
▪ | Power | : | 220V / 110V AC 50/60Hz | |
▪ | Temperature | : | -10~40℃ | |
▪ | Dimension | : | 450(W) x 200(D) x 245(425)(H) mm | |
▪ | Weight | : | About 7kg | |
▪ | Option | : | Main Unit | |
: | RPM/ Oil temp. | |||
: | Built-in printer | |||
: | NDF filter |